Analytical laboratory work requires much more
precise control of parameters than portable or field devices. The
Milwaukee Mi150 and Mi151 series will allow you to instantly and accurately know the
PH, Temperature and ORP (Rust Reduction Potential) values in any solution or liquid to be analyzed.
They have an advanced internal
microprocessor , which improves the
speed of reading the values and their precision. This reading is displayed on a high-contrast
LCD screen , and on a practical control monitor, which makes it easy to
calibrate , in up to 7 different positions.
The range consists of two devices:
My 150: It is a laboratory pH and temperature meter. It includes a PH range between -2 and 16 with a resolution of 0.01PH and an accuracy of +/- 0.01PH. The temperature range is -20 to 120ºC with a resolution of 0.1ºC and an accuracy of +/- 0.4ºC.
It has automatic
calibration of PH in 1 or 2 points, as well as automatic temperature compensation. Both the calibration and the possibility of memorizing the values are controlled from the same device.
The equipment incorporates the MA917B / 1 measurement
probes for PH and the MA831R for temperature. Also included are the pH calibration envelopes at 4, 7 and 10 and another envelope for cleaning the probes and electrodes.
The equipment is connected to the general current through a
12VDC adapter which is included.
My 151: It is a laboratory meter of PH, ORP and temperature. It includes a PH range between -2 and 16 with a resolution of 0.01PH and an accuracy of +/- 0.01PH. The ORP range is from +/- 699.9mV to +/- 1999mV, with a resolution of +/- 0.1mV or 1mV and an accuracy of 0.2mV. The temperature range is -20 to 120ºC with a resolution of 0.1ºC and an accuracy of +/- 0.4ºC.
It has automatic
calibration of PH in 1 or 2 points with 7 memorizable buffers, as well as
automatic temperature compensation . Both the calibration and the possibility of memorizing the values are controlled from the same device.
The equipment incorporates the MA917B / 1 measurement
probes for PH and the MA831R for temperature. Probes for ORP measurement are not included, and are the MA924 / B1 and SE300. Also included are the pH calibration envelopes at 4, 7 and 10 and another envelope for cleaning the probes and electrodes.
The equipment is connected to the general current through a
12VDC adapter which is included.
Milwaukee Mi150 / 151 Lab Combo Meter: My 150
Combined PH meter and laboratory temperature Mi150Milwaukee Mi150 / 151 Lab Combo Meter: My 151
Combined laboratory meter for PH, ORP and Tª Mi151