The
Testo 176P1 datalogger is a
high-performance, high-capacity, and precision storage device capable of continuously recording
temperature, humidity, and pressure values using various pluggable probes. The device supports up to
5 channels of data.
It allows the
simultaneous measurement of 2 temperature
values and 2 humidity values, thanks to the availability of connection of
external probes , which are essential for operation. These probes must be purchased separately. Values are displayed on an easy-to-read
LCD screen , which also tells you the trend and status of the battery.
The
temperature is measured with NTC type sensor probes, with a range between -20 and 70ºC, being able to connect up to 2 different probes. The resolution is 0.1ºC and its precision varies between +/- 0.2 and +/- 0.4ºC.
Humidity is measured through a capacitive sensor, which records values from 0 to 100%. Up to 2 different humidity probes can be attached. Use of this device in environments close to saturation / condensation is not recommended. The resolution is 0.1%.
Atmospheric pressure is measured by an absolute pressure sensor with a range from 600 to 1100mBar, with a resolution of 1mBar.
Another great advantage of these devices is the
large storage
capacity , up to
2 million data and with a battery life of up to
8 years . In this way we have a team with a long service life and that can capture records
continuously in a long time exposure.
To
download and view the data on a computer, a USB / SD card cable and software are required, which can be purchased in 3 versions:
- ComSoft Basic- free
- ComSoft Professional
- ComSoft CFR 21 part 11
Package includes:
- Data logger testo
- Wall mount
- Padlock
- Battery
- Calibration protocol
Characteristics:
- Measurements: 103 x 63 x 33 mm
- Operating temperature: -20 to +70 ºC
- Protection class: IP54
- Channels: 1 external; 4 internal
- Warranty: 2 years
- Battery type: 1 lithium battery (TL-5903)
- Autonomy: 8 years (15 'measurement interval at +25 ° C)
- Memory: 2,000,000 measured value
- Storage temperature: -40 to +85 ºC
- Range: -20 to +70 ºC
- Accuracy: ± 0.2 ºC (-20 to +70 ºC)
- ± 0.4 ºC (Rest range)
- Resolution: 0.1 ºC
- Range: 0 to 100% RH *
- Accuracy: depending on the probe chosen
- Resolution: 0.1% RH
- * Unsuitable for condensing atmospheres. For use in continuous high humidity (> 80% RH at ≤30 ° C> 12 h,> 60% RH at> 30 ° C> 12 h), please contact our advisory department.
- Range: 600 to 1100 mbar
- Accuracy: ± 3 mbar (0 to +50 ºC)
- Resolution: 1 mbar